Activated Carbon Siloxane VOC Removal System Vessel For Landfill Gas Purification Line
| Siloxane Removal: | Above 95% On D5 Basis | VOC Removal: | Above 90% |
| Design Pressure: | 6 Bar | Media Type: | Impregnated Activated Carbon, 4 Mm Pellet |
| Media Life: | 12 To 18 Months | Change Out Time: | 8 Hours With Two Operators |
| High Light: | Activated Carbon VOC Removal System,Landfill VOC Removal System,Siloxane VOC Removal System |
||
Landfill gas carries siloxanes and volatile organic compounds that survive ordinary desulfurization and then burn into abrasive silica inside an engine or a boiler. The deposit coats pistons and spark plugs, raises exhaust temperature and shortens overhaul intervals. This vessel is placed after desulfurization and before the gas engine or upgrading unit to strip those trace contaminants out.
- Siloxane removal above 95 percent expressed on a D5 basis
- VOC removal above 90 percent, including terpenes and halogenated traces
- Vessel design pressure 6 bar, tested at 1.5 times design
- Media life 12 to 18 months depending on inlet siloxane load
- Media change out completed in about 8 hours by two operators
Impregnated activated carbon in 4 mm pellet form is used for low pressure drop and high working capacity. The bed sits on a stainless support grid with a graded gravel layer, and the vessel is fitted with top and bottom manways, a sampling port per layer and a media discharge nozzle. Spent carbon is removed by vacuum and can be returned for regeneration or disposal through a licensed route.
Where the upstream stage is a biological or iron based desulfurizer, the drain and recovery port on this vessel accepts sulfur laden condensate so sulfur cake can be collected rather than flushed to drain. That keeps the sulphur out of the wastewater and gives the operator a saleable or safely disposable by-product.
Carbon steel shell with epoxy lining is standard, with SS316 offered for high chloride landfill sites. The vessel is fitted with a pressure relief valve, flame arrestor option and gas detection tapping. Earthing bosses are welded in place for static dissipation.
Used on landfill gas to engine projects, on landfill gas upgrading to biomethane, and on sewage sludge digesters where solvent or industrial waste raises VOC load. For very high siloxane sites, two vessels in lead-lag arrangement extend the interval between change outs.
Share your gas analysis and engine warranty terms, and we will size the carbon bed for your site.