Activated Carbon Siloxane VOC Removal System Vessel For Landfill Gas Purification Line

Basic Properties
Place of Origin: Qingdao, China
Brand Name: Hanwei
Certification: ISO 9001
Trading Properties
Minimum Order Quantity: 1 Set
Price: Get Custom Quote
Payment Terms: T/T,D/P,L/C
Supply Ability: 10 Sets per Month
Specifications
Siloxane Removal: Above 95% On D5 Basis VOC Removal: Above 90%
Design Pressure: 6 Bar Media Type: Impregnated Activated Carbon, 4 Mm Pellet
Media Life: 12 To 18 Months Change Out Time: 8 Hours With Two Operators
High Light:

Activated Carbon VOC Removal System

,

Landfill VOC Removal System

,

Siloxane VOC Removal System

Product Description
The Landfill Gas Problem

Landfill gas carries siloxanes and volatile organic compounds that survive ordinary desulfurization and then burn into abrasive silica inside an engine or a boiler. The deposit coats pistons and spark plugs, raises exhaust temperature and shortens overhaul intervals. This vessel is placed after desulfurization and before the gas engine or upgrading unit to strip those trace contaminants out.

Performance Data
  • Siloxane removal above 95 percent expressed on a D5 basis
  • VOC removal above 90 percent, including terpenes and halogenated traces
  • Vessel design pressure 6 bar, tested at 1.5 times design
  • Media life 12 to 18 months depending on inlet siloxane load
  • Media change out completed in about 8 hours by two operators
Media and Bed Design

Impregnated activated carbon in 4 mm pellet form is used for low pressure drop and high working capacity. The bed sits on a stainless support grid with a graded gravel layer, and the vessel is fitted with top and bottom manways, a sampling port per layer and a media discharge nozzle. Spent carbon is removed by vacuum and can be returned for regeneration or disposal through a licensed route.

Sulfur Recovery Port

Where the upstream stage is a biological or iron based desulfurizer, the drain and recovery port on this vessel accepts sulfur laden condensate so sulfur cake can be collected rather than flushed to drain. That keeps the sulphur out of the wastewater and gives the operator a saleable or safely disposable by-product.

Materials and Safety

Carbon steel shell with epoxy lining is standard, with SS316 offered for high chloride landfill sites. The vessel is fitted with a pressure relief valve, flame arrestor option and gas detection tapping. Earthing bosses are welded in place for static dissipation.

Application Notes

Used on landfill gas to engine projects, on landfill gas upgrading to biomethane, and on sewage sludge digesters where solvent or industrial waste raises VOC load. For very high siloxane sites, two vessels in lead-lag arrangement extend the interval between change outs.

Share your gas analysis and engine warranty terms, and we will size the carbon bed for your site.