Containerized Biogas Dehydration Skid Unit With Online H2S CH4 Gas Analyzer

Basic Properties
Place of Origin: Qingdao, China
Brand Name: Hanwei
Certification: ISO 9001
Trading Properties
Minimum Order Quantity: 1 Set
Price: Get Custom Quote
Payment Terms: T/T,D/P,L/C
Supply Ability: 12 Sets per Month
Specifications
Analyzer Output: 4-20 MA Plus Modbus RTU Analyzer Range: H2S 0-100 Ppm, CH4 0-100 Percent
Outlet Dew Point: 5 C Or Lower At Line Pressure Skid Dimensions: 3.0 X 2.4 X 2.6 M, 20 Ft Frame
Knock Out Drum: Vertical Separator, 1.2 M3 Inlet Condition: Saturated Biogas At 35 C
High Light:

Biogas Dehydration Skid Unit

,

Containerized Biogas Dehydration Skid

Product Description
Why Dry the Gas First

Water vapour is the quiet destroyer of a desulfurization or upgrading train. It blinds analyzers, blinds media, corrodes carbon steel and pushes the dew point of the product gas out of specification. This skid removes that problem before the gas reaches the media bed or the membrane, and it reports gas quality continuously so the operator can act on drift.

Dehydration Section
  • Knock out drum removes free condensate with a demister element
  • Refrigerated dryer pulls the dew point to 5 C or lower at line pressure
  • Cyclone separator with automatic drain traps, no manual purging
  • Plate heat exchanger recovers cold from the outlet gas to cut chiller load
Analysis Section

The analyzer panel reads H2S in the 0-100 ppm band and methane across 0-100 percent, with the two channels logged together. Readings go out on 4-20 mA for the plant PLC and on Modbus RTU for SCADA, and high H2S triggers a relay that can trip the gas train or divert flow to flare. Sample conditioning includes a filter, a pressure regulator and a coalescing trap so the sensor sees clean, dry gas.

Packaging and Site Work

Everything is mounted on a 20 ft frame, piped, wired and factory tested before shipment. On site the unit needs a flat pad, inlet and outlet connections, drain to a condensate sump and a single power feed. Most installations are complete within two days, with no field fabrication and no refrigeration technician required.

Operating Notes

Typical power draw is 3 to 5 kW depending on ambient temperature and flow. In cold climates the frame is supplied with trace heating on the drain lines. Analyzer cells are user replaceable and calibrated with bottled span gas at twelve-month intervals.

Where It Fits

Agricultural digesters, landfill gas wells and sludge digestion plants that feed CHP engines, boilers or upgrading units. The skid is also used as a retrofit ahead of an existing desulfurizer that keeps suffering from wet media.

Tell us your flow, pressure and target dew point, and we will configure the skid and analyzer ranges for your plant.